{"id":3767,"date":"2018-02-07T15:14:12","date_gmt":"2018-02-07T14:14:12","guid":{"rendered":"http:\/\/tomaskalabis.com\/wordpress\/?p=3767"},"modified":"2021-01-22T13:56:13","modified_gmt":"2021-01-22T12:56:13","slug":"dell-emc-sc-series-storage-and-microsoft-multipath-i","status":"publish","type":"post","link":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/","title":{"rendered":"Windows Server 2016 &#8211; MPIO and SAS conectivity  with Dell EMC SC Storage Series"},"content":{"rendered":"<h3>Windows Server 2016 &#8211; MPIO and SAS conectivity with Dell EMC SC Storage Series<\/h3>\n<p>This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC SC (Compellent) Storage Series.<\/p>\n<h4>Install the MPIO feature<\/h4>\n<p>Run Powershell with Administrator\u00a0 privileges and run:<\/p>\n<pre class=\"lang:ps decode:true\">Enable-WindowsOptionalFeature \u2013Online \u2013FeatureName MultiPathIO<\/pre>\n<p>and reboot the server.<\/p>\n<h4>Configuration with Dell Storage Manager Client<\/h4>\n<p>Download latest DELL Storage Manager Client from <a href=\"http:\/\/www.dell.com\/support\/home\/us\/en\/19\/Drivers\/DriversDetails?driverId=NWG3X\" target=\"_blank\" rel=\"noopener noreferrer\">Dell support website<\/a> (latest version\u00a02016 R3.11 &#8211; 07.02.2017)<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas1.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3768\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas1-494x371.jpg\" alt=\"\" width=\"494\" height=\"371\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas1-494x371.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas1-288x216.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas1.jpg 688w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>and install it on your Windows Server 2016<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas2.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3769\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas2-494x325.jpg\" alt=\"\" width=\"494\" height=\"325\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas2-494x325.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas2-288x189.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas2.jpg 668w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>run DSM Client and choose third option &#8222;Configure this host to access a Storage Center&#8220;<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas3.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3770\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas3-494x308.jpg\" alt=\"\" width=\"494\" height=\"308\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas3-494x308.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas3-288x180.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas3-480x300.jpg 480w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas3.jpg 583w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>and log in to your Storage Center.<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas4.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3771\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas4-494x434.jpg\" alt=\"\" width=\"494\" height=\"434\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas4-494x434.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas4-288x253.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas4-768x675.jpg 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas4.jpg 781w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>click &gt; Next<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas5.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3772\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas5-494x435.jpg\" alt=\"\" width=\"494\" height=\"435\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas5-494x435.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas5-288x254.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas5-768x677.jpg 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas5.jpg 783w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>Verify localhost information and click to &gt; Next<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas6.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3773\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas6-494x435.jpg\" alt=\"\" width=\"494\" height=\"435\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas6-494x435.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas6-288x253.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas6-768x676.jpg 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas6.jpg 783w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>&#8222;The preferred method to create a new server object on SC Series storage is to use the host configuration<br \/>\nwizard on the launch screen of the Dell Storage Manager client. One of the main benefits of this method of<br \/>\nserver creation is the wizard will automatically adjust the host server MPIO time-out settings in the Windows registry to match the current best practices &#8220;<br \/>\n<strong>reboot is required<\/strong><\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas7jpg.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3774\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas7jpg-494x250.jpg\" alt=\"\" width=\"494\" height=\"250\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas7jpg-494x250.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas7jpg-288x146.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas7jpg-768x389.jpg 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas7jpg.jpg 1578w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas8jpg.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3775\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas8jpg-386x494.jpg\" alt=\"\" width=\"386\" height=\"494\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas8jpg-386x494.jpg 386w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas8jpg-225x288.jpg 225w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas8jpg.jpg 395w\" sizes=\"(max-width: 386px) 100vw, 386px\" \/><\/a><\/p>\n<p>After installing the MPIO feature and rebooting, if configuring MPIO for iSCSI or SAS, launch the MPIO configuration utility and <strong>under the Discover Multi-Paths tab, select Add Support for iSCSI devices or SAS devices as appropriate and click Add.<\/strong><\/p>\n<h4>Configure MPIO<\/h4>\n<p>The best practices for using SC storage with SAS connectivity and Windows Server 2016 is use <strong>Round Robin with Subset.<\/strong><\/p>\n<p>The default load balancing policy is set to none, you can verify it with command:<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas9jpg.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3776\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas9jpg-494x131.jpg\" alt=\"\" width=\"494\" height=\"131\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas9jpg-494x131.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas9jpg-288x77.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas9jpg.jpg 572w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<pre class=\"lang:ps decode:true \">Get-MSDSMGlobalDefaultLoadBalancePolicy<\/pre>\n<p>To change the default load balancing policy to RRWS use PowerShell command:<\/p>\n<pre class=\"lang:ps decode:true\">Set-MSDSMGlobalDefaultLoadBalancePolicy \u2013Policy \"RR\"<\/pre>\n<p>To verify, that your disks use RRWS use command:<\/p>\n<p><a href=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas10jpg.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-3777\" src=\"http:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas10jpg-494x127.jpg\" alt=\"\" width=\"494\" height=\"127\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas10jpg-494x127.jpg 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas10jpg-288x74.jpg 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas10jpg-768x198.jpg 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2018\/02\/SCV-sas10jpg.jpg 832w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<pre class=\"lang:ps decode:true\">mpclaim -s -d<\/pre>\n<h4>What is RRWS ?<\/h4>\n<div id=\"GUID-6DEE96B4-C7B6-4ACD-A582-3A8FAD405481\" class=\"nested0\" xml:lang=\"en-us\" data-id=\"GUID-6DEE96B4-C7B6-4ACD-A582-3A8FAD405481\">\n<div>\n<div id=\"GUID-6DEE96B4-C7B6-4ACD-A582-3A8FAD405481__GUID-683E7711-552A-4F9A-9408-174D98E2DDD5\" class=\"section\" data-id=\"GUID-683E7711-552A-4F9A-9408-174D98E2DDD5\">\n<p>The round robin with subset I\/O load balance policy routes I\/O requests, in rotation, to each available data path to the RAID controller module that owns the virtual disks. This policy treats all paths to the RAID controller module that owns the virtual disk equally for I\/O activity. Paths to the secondary RAID controller module are ignored until ownership changes. The basic assumption for the round-robin policy is that the data paths are equal. With mixed host support, the data paths might have different bandwidths or different data transfer speeds.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Windows Server 2016 &#8211; MPIO and SAS conectivity with Dell EMC SC Storage Series This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC &#8230;<\/p>\n","protected":false},"author":2,"featured_media":2674,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[229],"tags":[256,281,285,284,230],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Windows Server 2016 - MPIO and SAS conectivity with Dell EMC SC Storage Series - tomaskalabis.com<\/title>\n<meta name=\"description\" content=\"This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC SC (Compellent) Storage Serie\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/\" \/>\n<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Windows Server 2016 - MPIO and SAS conectivity with Dell EMC SC Storage Series - tomaskalabis.com\" \/>\n<meta property=\"og:description\" content=\"This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC SC (Compellent) Storage Serie\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/\" \/>\n<meta property=\"og:site_name\" content=\"tomaskalabis.com\" \/>\n<meta property=\"article:published_time\" content=\"2018-02-07T14:14:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-01-22T12:56:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png\" \/>\n\t<meta property=\"og:image:width\" content=\"215\" \/>\n\t<meta property=\"og:image:height\" content=\"174\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tomas Kalabis\" \/>\n<meta name=\"twitter:label1\" content=\"Napsal(a)\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tomas Kalabis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Odhadovan\u00e1 doba \u010dten\u00ed\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/\",\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/\",\"name\":\"Windows Server 2016 - MPIO and SAS conectivity with Dell EMC SC Storage Series - tomaskalabis.com\",\"isPartOf\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png\",\"datePublished\":\"2018-02-07T14:14:12+00:00\",\"dateModified\":\"2021-01-22T12:56:13+00:00\",\"author\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6\"},\"description\":\"This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC SC (Compellent) Storage Serie\",\"breadcrumb\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#breadcrumb\"},\"inLanguage\":\"cs\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#primaryimage\",\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png\",\"contentUrl\":\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png\",\"width\":215,\"height\":174},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/tomaskalabis.com\/wordpress\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Windows Server 2016 &#8211; MPIO and SAS conectivity with Dell EMC SC Storage Series\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#website\",\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/\",\"name\":\"tomaskalabis.com\",\"description\":\"my personal blog\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/tomaskalabis.com\/wordpress\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"cs\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6\",\"name\":\"Tomas Kalabis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g\",\"caption\":\"Tomas Kalabis\"},\"sameAs\":[\"https:\/\/x.com\/tomaskalabis\"],\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/author\/kalabis\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Windows Server 2016 - MPIO and SAS conectivity with Dell EMC SC Storage Series - tomaskalabis.com","description":"This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC SC (Compellent) Storage Serie","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/","og_locale":"cs_CZ","og_type":"article","og_title":"Windows Server 2016 - MPIO and SAS conectivity with Dell EMC SC Storage Series - tomaskalabis.com","og_description":"This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC SC (Compellent) Storage Serie","og_url":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/","og_site_name":"tomaskalabis.com","article_published_time":"2018-02-07T14:14:12+00:00","article_modified_time":"2021-01-22T12:56:13+00:00","og_image":[{"width":215,"height":174,"url":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png","type":"image\/png"}],"author":"Tomas Kalabis","twitter_misc":{"Napsal(a)":"Tomas Kalabis","Odhadovan\u00e1 doba \u010dten\u00ed":"4 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/","url":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/","name":"Windows Server 2016 - MPIO and SAS conectivity with Dell EMC SC Storage Series - tomaskalabis.com","isPartOf":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#primaryimage"},"image":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#primaryimage"},"thumbnailUrl":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png","datePublished":"2018-02-07T14:14:12+00:00","dateModified":"2021-01-22T12:56:13+00:00","author":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6"},"description":"This article is focused how to set up MPIO in Windows Server 2016 and DELL EMC SC (Compellent) Storage Serie","breadcrumb":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#breadcrumb"},"inLanguage":"cs","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/"]}]},{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#primaryimage","url":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png","contentUrl":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png","width":215,"height":174},{"@type":"BreadcrumbList","@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-emc-sc-series-storage-and-microsoft-multipath-i\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tomaskalabis.com\/wordpress\/"},{"@type":"ListItem","position":2,"name":"Windows Server 2016 &#8211; MPIO and SAS conectivity with Dell EMC SC Storage Series"}]},{"@type":"WebSite","@id":"https:\/\/tomaskalabis.com\/wordpress\/#website","url":"https:\/\/tomaskalabis.com\/wordpress\/","name":"tomaskalabis.com","description":"my personal blog","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tomaskalabis.com\/wordpress\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"cs"},{"@type":"Person","@id":"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6","name":"Tomas Kalabis","image":{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g","caption":"Tomas Kalabis"},"sameAs":["https:\/\/x.com\/tomaskalabis"],"url":"https:\/\/tomaskalabis.com\/wordpress\/author\/kalabis\/"}]}},"jetpack_featured_media_url":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2016\/01\/winsrv2016.png","_links":{"self":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts\/3767"}],"collection":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/comments?post=3767"}],"version-history":[{"count":2,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts\/3767\/revisions"}],"predecessor-version":[{"id":6728,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts\/3767\/revisions\/6728"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/media\/2674"}],"wp:attachment":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/media?parent=3767"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/categories?post=3767"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/tags?post=3767"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}