{"id":7590,"date":"2025-11-12T10:08:55","date_gmt":"2025-11-12T09:08:55","guid":{"rendered":"https:\/\/tomaskalabis.com\/wordpress\/?p=7590"},"modified":"2025-11-12T10:08:56","modified_gmt":"2025-11-12T09:08:56","slug":"dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged","status":"publish","type":"post","link":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/","title":{"rendered":"DELL SC &#8211; Adding new SAS HDDs to Compellent SD3020- unmanaged"},"content":{"rendered":"\n<h3>DELL SC &#8211; Adding new SAS HDDs to Compellent SD3020- unmanaged<\/h3>\n<p style=\"text-align: center;\">One of our customers bought a new NVMe storage array, so he decided to use the older SC3020 for testing and lab purposes. He also had an older SC2020 array, which contained several \u201cfree\u201d 1.92 TB SAS disks.<\/p>\n<p><a href=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/Screenshot-2025-11-07-at-7.18.30.png\"><img decoding=\"async\" loading=\"lazy\" class=\"size-large wp-image-7591 aligncenter\" src=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/Screenshot-2025-11-07-at-7.18.30-494x138.png\" alt=\"\" width=\"494\" height=\"138\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/Screenshot-2025-11-07-at-7.18.30-494x138.png 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/Screenshot-2025-11-07-at-7.18.30-288x80.png 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/Screenshot-2025-11-07-at-7.18.30-768x214.png 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/Screenshot-2025-11-07-at-7.18.30.png 1406w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p style=\"text-align: center;\" data-start=\"328\" data-end=\"565\">We wanted to reuse the disks from the SC2020 in the SC3020. My colleague removed the SAS disks from the SC2020 and inserted them into the SC3020. After assigning the disks to the correct disk group, the disks appeared as <strong data-start=\"549\" data-end=\"565\">\u201cUnmanaged.\u201d<\/strong><\/p>\n<p data-start=\"106\" data-end=\"151\">\u00a0<\/p>\n<p style=\"text-align: center;\" data-start=\"153\" data-end=\"383\">Unfortunately, I didn\u2019t have console access to the array, because the serial cable wasn\u2019t connected and the storage was located in a different site. I worked around it by launching the <strong data-start=\"338\" data-end=\"355\">iDRAC console<\/strong> on the active controller.<\/p>\n<p data-start=\"153\" data-end=\"383\"><a href=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image002.png\"><img decoding=\"async\" loading=\"lazy\" class=\"size-large wp-image-7592 aligncenter\" src=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image002-494x219.png\" alt=\"\" width=\"494\" height=\"219\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image002-494x219.png 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image002-288x128.png 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image002-768x340.png 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image002-1536x681.png 1536w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image002.png 1726w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p style=\"text-align: center;\" data-start=\"153\" data-end=\"383\">I logged in as <strong data-start=\"400\" data-end=\"409\">admin<\/strong> and then ran the command:<\/p>\n<p style=\"text-align: center;\" data-start=\"153\" data-end=\"383\"><em><strong>shellaccess developer<\/strong><\/em><\/p>\n<p style=\"text-align: center;\" data-start=\"470\" data-end=\"609\">After that, I identified the indexes of the newly added disks through the <strong data-start=\"544\" data-end=\"558\">DSM client<\/strong> and executed the following command for each one:<\/p>\n<div class=\"contain-inline-size rounded-2xl relative bg-token-sidebar-surface-primary\">\n<div class=\"sticky top-9\">\n<div class=\"absolute end-0 bottom-0 flex h-9 items-center pe-2\">\n<div class=\"bg-token-bg-elevated-secondary text-token-text-secondary flex items-center gap-4 rounded-sm px-2 font-sans text-xs\" style=\"text-align: center;\"><em><strong>disk manage &lt;index number&gt;<\/strong><\/em><\/div>\n<div>\u00a0<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p style=\"text-align: center;\" data-start=\"647\" data-end=\"795\">Once I did that, the disks immediately appeared as <strong data-start=\"698\" data-end=\"709\">Managed<\/strong>, and the Storage Center automatically started <strong data-start=\"756\" data-end=\"771\">rebalancing<\/strong>the data across them.<\/p>\n<p data-start=\"647\" data-end=\"795\"><a href=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image001111.png\"><img decoding=\"async\" loading=\"lazy\" class=\"size-large wp-image-7593 aligncenter\" src=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image001111-494x89.png\" alt=\"\" width=\"494\" height=\"89\" srcset=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image001111-494x89.png 494w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image001111-288x52.png 288w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image001111-768x138.png 768w, https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2025\/11\/image001111.png 1389w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"<p>DELL SC &#8211; Adding new SAS HDDs to Compellent SD3020- unmanaged One of our customers bought a new NVMe storage array, so he decided to use the older SC3020 for &#8230;<\/p>\n","protected":false},"author":2,"featured_media":3495,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[412],"tags":[256,284,316],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DELL SC - Adding new SAS HDDs to Compellent SD3020- unmanaged - tomaskalabis.com<\/title>\n<meta name=\"description\" content=\"How I solved the issue with unmanaged SAS drives on a Dell SC3020 after moving them from an SC2020 array. A quick workaround using iDRAC console access and the shellaccess developer command to bring disks back to a managed state.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/\" \/>\n<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DELL SC - Adding new SAS HDDs to Compellent SD3020- unmanaged - tomaskalabis.com\" \/>\n<meta property=\"og:description\" content=\"How I solved the issue with unmanaged SAS drives on a Dell SC3020 after moving them from an SC2020 array. A quick workaround using iDRAC console access and the shellaccess developer command to bring disks back to a managed state.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/\" \/>\n<meta property=\"og:site_name\" content=\"tomaskalabis.com\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-12T09:08:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-12T09:08:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png\" \/>\n\t<meta property=\"og:image:width\" content=\"200\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tomas Kalabis\" \/>\n<meta name=\"twitter:label1\" content=\"Napsal(a)\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tomas Kalabis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Odhadovan\u00e1 doba \u010dten\u00ed\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/\",\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/\",\"name\":\"DELL SC - Adding new SAS HDDs to Compellent SD3020- unmanaged - tomaskalabis.com\",\"isPartOf\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png\",\"datePublished\":\"2025-11-12T09:08:55+00:00\",\"dateModified\":\"2025-11-12T09:08:56+00:00\",\"author\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6\"},\"description\":\"How I solved the issue with unmanaged SAS drives on a Dell SC3020 after moving them from an SC2020 array. A quick workaround using iDRAC console access and the shellaccess developer command to bring disks back to a managed state.\",\"breadcrumb\":{\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#breadcrumb\"},\"inLanguage\":\"cs\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#primaryimage\",\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png\",\"contentUrl\":\"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png\",\"width\":200,\"height\":200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/tomaskalabis.com\/wordpress\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"DELL SC &#8211; Adding new SAS HDDs to Compellent SD3020- unmanaged\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#website\",\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/\",\"name\":\"tomaskalabis.com\",\"description\":\"my personal blog\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/tomaskalabis.com\/wordpress\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"cs\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6\",\"name\":\"Tomas Kalabis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g\",\"caption\":\"Tomas Kalabis\"},\"sameAs\":[\"https:\/\/x.com\/tomaskalabis\"],\"url\":\"https:\/\/tomaskalabis.com\/wordpress\/author\/kalabis\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DELL SC - Adding new SAS HDDs to Compellent SD3020- unmanaged - tomaskalabis.com","description":"How I solved the issue with unmanaged SAS drives on a Dell SC3020 after moving them from an SC2020 array. A quick workaround using iDRAC console access and the shellaccess developer command to bring disks back to a managed state.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/","og_locale":"cs_CZ","og_type":"article","og_title":"DELL SC - Adding new SAS HDDs to Compellent SD3020- unmanaged - tomaskalabis.com","og_description":"How I solved the issue with unmanaged SAS drives on a Dell SC3020 after moving them from an SC2020 array. A quick workaround using iDRAC console access and the shellaccess developer command to bring disks back to a managed state.","og_url":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/","og_site_name":"tomaskalabis.com","article_published_time":"2025-11-12T09:08:55+00:00","article_modified_time":"2025-11-12T09:08:56+00:00","og_image":[{"width":200,"height":200,"url":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png","type":"image\/png"}],"author":"Tomas Kalabis","twitter_misc":{"Napsal(a)":"Tomas Kalabis","Odhadovan\u00e1 doba \u010dten\u00ed":"2 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/","url":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/","name":"DELL SC - Adding new SAS HDDs to Compellent SD3020- unmanaged - tomaskalabis.com","isPartOf":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#primaryimage"},"image":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#primaryimage"},"thumbnailUrl":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png","datePublished":"2025-11-12T09:08:55+00:00","dateModified":"2025-11-12T09:08:56+00:00","author":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6"},"description":"How I solved the issue with unmanaged SAS drives on a Dell SC3020 after moving them from an SC2020 array. A quick workaround using iDRAC console access and the shellaccess developer command to bring disks back to a managed state.","breadcrumb":{"@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#breadcrumb"},"inLanguage":"cs","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/"]}]},{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#primaryimage","url":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png","contentUrl":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png","width":200,"height":200},{"@type":"BreadcrumbList","@id":"https:\/\/tomaskalabis.com\/wordpress\/dell-sc-adding-new-sas-hdds-to-compellent-sd3020-unmanaged\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tomaskalabis.com\/wordpress\/"},{"@type":"ListItem","position":2,"name":"DELL SC &#8211; Adding new SAS HDDs to Compellent SD3020- unmanaged"}]},{"@type":"WebSite","@id":"https:\/\/tomaskalabis.com\/wordpress\/#website","url":"https:\/\/tomaskalabis.com\/wordpress\/","name":"tomaskalabis.com","description":"my personal blog","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tomaskalabis.com\/wordpress\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"cs"},{"@type":"Person","@id":"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/8e7e83f618a561ed3734a38cef4cf1d6","name":"Tomas Kalabis","image":{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/tomaskalabis.com\/wordpress\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9f7e4796b38d5720e8a07b918f423311?s=96&d=retro&r=g","caption":"Tomas Kalabis"},"sameAs":["https:\/\/x.com\/tomaskalabis"],"url":"https:\/\/tomaskalabis.com\/wordpress\/author\/kalabis\/"}]}},"jetpack_featured_media_url":"https:\/\/tomaskalabis.com\/wordpress\/wp-content\/uploads\/2017\/01\/dell_emc.png","_links":{"self":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts\/7590"}],"collection":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/comments?post=7590"}],"version-history":[{"count":1,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts\/7590\/revisions"}],"predecessor-version":[{"id":7594,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/posts\/7590\/revisions\/7594"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/media\/3495"}],"wp:attachment":[{"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/media?parent=7590"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/categories?post=7590"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tomaskalabis.com\/wordpress\/wp-json\/wp\/v2\/tags?post=7590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}